In this example, we will see all the system elements in operation.
The model represents an automated production line where packages arrive one by one, are weighed on a scale, and based on their weight, are diverted to one path or another using a pneumatic piston.
Process Description
-
Entry Detection
A door sensor detects the arrival of a new package (symbolizing a product entering the zone).
Each detection generates a new entity in GPSS-Plus. -
Unitary Flow Control
A restroom acts as a unitary releaser, allowing packages to pass one at a time toward the scale.
The next package only advances once the previous one has finished weighing. -
Weighing
Upon reaching the scale, the entity activates the sensor (Device_Scale_Trigger = 1).
When the weight stabilizes, the system assigns the read value to the entity. -
Classification
If the weight exceeds a threshold (pesoLimite), the piston is activated (Device_Piston_Trigger = 1), diverting the package to the heavy zone.
If not, it continues straight to the light zone. -
Synchronization with Physical Actuators
The piston retracts automatically.
GPSS-Plus subscribes to the piston state (Device_Piston_IsExtended) to know when it is ready for the next cycle.
System Architecture:
[Door Sensor] -> generates entity
↓
[Unitary Releaser]
↓
[Scale] <-> OPC-UA Device_Scale_Weight
↓
[Separator / Piston]
↓
[Light Exit] / [Heavy Exit]
Example
SYSTEM {TYPE:PRE_RUN,TRIGGER:PRE_RUN}
SYSTEM {TYPE:OPTIONS, REAL_TIME:1}
Restroom {NAME:LiberadorUnitario,X:155,Y:332}
Queuer {NAME:zonaBascula,X:163,Y:32}
Graphic {NAME:lineZonaBascula,Type:LINE,color:#FF0000, X1:82,Y1:64,X2:260,Y2:65}
Restroom {NAME:RestroomBascula,X:226,Y:110}
initial pesoLimite,8
Initial options,{user:"user", pass:"1234"}
BRIDGER {NAME:bridge1,X:733,Y:556
,SERVER:"wss://bridger.gpss-plus.com:3000"
,CLIENT:"opc.tcp://opcua.gpss-plus.com:4840"
,OPTIONS:V$options
,on_error:bridge1_on_error
}
POSITION {NAME:POS1,X:97,Y:437}
POSITION {NAME:POS2,X:95,Y:183}
POSITION {NAME:PosBascula,X:225,Y:199}
POSITION {NAME:PosSeparador,X:387,Y:201}
POSITION {NAME:PosPesados,X:513,Y:302}
POSITION {NAME:PosPesados2,X:594,Y:302}
POSITION {NAME:PosLigeros,X:511,Y:197}
POSITION {NAME:PosLigeros2,X:592,Y:197}
Graphic {NAME:Text1,Type:TEXT,X:167,Y:484,Text:"On OPEN"}
Graphic {NAME:TextError,Type:TEXT,X:424,Y:582,Text:"Error"}
Graphic {NAME:lineBascula,Type:LINE,color:#FF0000, X1:191,Y1:176,X2:263,Y2:176}
Graphic {NAME:txtBascula,Type:TEXT,X:226,Y:156,Text:"bascula"}
Graphic {NAME:lineSeparador,Type:LINE,color:#FF0000, X1:363,Y1:201,X2:432,Y2:201}
Graphic {NAME:txtSeparador,Type:TEXT,X:394,Y:143,Text:"separador"}
START 10
;*****************************************************
PROCEDURE PRE_RUN
BRIDGE_SUBSCRIPTION { NAME: bridge1
, VARIABLE: "Sensor_Door_IsOpen"
, TRIGGER: on_open
}
savevalue pesoActual,0
savevalue pesoAnterior,X$pesoActual
BRIDGE_SUBSCRIPTION { NAME: bridge1
, VARIABLE: "Device_Scale_Weight"
, TRIGGER: on_subscription_bascula
}
BRIDGE_SUBSCRIPTION { NAME: bridge1
, VARIABLE: "Device_Piston_IsExtended"
, TRIGGER: on_subscription_piston
}
ASSIGN values, { Device_Scale_Trigger: 0 }
BRIDGE_WRITE { name:bridge1, VALUES:V$values ,TRIGGER:on_write}
TERMINATE_VE
ENDPROCEDURE
;*****************************************************
GENERATE 0,0,0,0 {NAME:GEN1,X:91,Y:547}
ADVANCE 5,0 {TO:POS1,flow:1}
ADVANCE 5,0 {TO:LiberadorUnitario,flow:1}
if (R$(zonaBascula,in)>0)
rest LiberadorUnitario
endif
queue zonaBascula
ADVANCE 5,0 {TO:POS2,flow:1}
ADVANCE 5,0 {TO:PosBascula,flow:1}
ASSIGN values, { Device_Scale_Trigger: 1 }
BRIDGE_WRITE { name:bridge1, VALUES:V$values ,TRIGGER:on_write}
rest RestroomBascula
depart zonaBascula
call liberarRestroomBascula
ADVANCE 2
mod {subtitle:"P$peso Kg"}
if (P$peso > X$pesoLimite)
mod {color:"red"}
else
mod {color:"green"}
endif
ASSIGN values, { Device_Scale_Trigger: 0 }
BRIDGE_WRITE { name:bridge1, VALUES:V$values ,TRIGGER:on_write}
timeout moverPiston,4.3,P$peso
ADVANCE 5,0 {TO:PosSeparador,flow:1}
if (P$peso > X$pesoLimite)
ADVANCE 3,0 {TO:PosPesados}
ADVANCE 3,0 {TO:PosPesados2,flow:1}
else
ADVANCE 3,0 {TO:PosLigeros}
ADVANCE 3,0 {TO:PosLigeros2,flow:1}
endif
ENDGENERATE 1
;----------------------------------------------------------------------------
procedure on_open
move {name:Text1,TEXT:"DOOR P$(PARAM_A.VALUE)"}
if (P$(PARAM_A.VALUE.EXIST))
if (P$(PARAM_A.VALUE)==1)
NEW GEN1
endif
endif
TERMINATE_VE
endprocedure
procedure bridge1_on_error
move {name:TextError,TEXT:"P$PARAM_A"}
TERMINATE_VE
endprocedure
;-------------------------
procedure on_subscription_bascula
savevalue pesoActual,P$(PARAM_A.VALUE)
move {name:txtBascula,TEXT:"X$pesoActual Kg"}
if (ABS(X$pesoAnterior-X$pesoActual)<=0.1 && X$pesoActual>1)
FOREACH entidad, IN_RESOURCE, RestroomBascula
assign peso,round(X$pesoActual,1), P$entidad
ENDFOREACH
wake RestroomBascula
endif
savevalue pesoAnterior,X$pesoActual
TERMINATE_VE
endprocedure
;-------------------------
procedure on_write
TERMINATE_VE
endprocedure
procedure on_subscription_piston
if (P$(PARAM_A.VALUE)==1)
move {name:lineSeparador,Y2:220}
else
move {name:lineSeparador,Y2:200}
endif
move {name:txtSeparador,text:"Piston P$(PARAM_A.VALUE)"}
TERMINATE_VE
endprocedure
procedure liberarRestroomBascula
assign hecho,0
FOREACH entidad, IN_RESOURCE, zonaBascula
if (P$hecho==0)
wake RestroomBascula,P$entidad
endif
assign hecho,1
ENDFOREACH
endprocedure
procedure moverPiston
if (P$PARAM_A>X$pesoLimite)
ASSIGN values, { Device_Piston_Trigger: 1 }
BRIDGE_WRITE { name:bridge1, VALUES:V$values, TRIGGER:on_write }
assign tmp,"heavy"
else
assign tmp,"light"
endif
TERMINATE_VE
endprocedure